Get desktop application:
View/edit binary Protocol Buffers messages
Used in: evse.v1.EVSE
CONNECTOR_STATUS_UNSPECIFIED = 0
CONNECTOR_STATUS_AVAILABLE = 1
CONNECTOR_STATUS_PREPARING = 2
CONNECTOR_STATUS_CHARGING = 3
CONNECTOR_STATUS_FINISHING = 4
CONNECTOR_STATUS_UNAVAILABLE = 5
CONNECTOR_STATUS_SUSPENDED_EVSE = 6
CONNECTOR_STATUS_SUSPENDED_EV = 7
CONNECTOR_STATUS_RESERVED = 8
CONNECTOR_STATUS_FAULTED = 9
CONNECTOR_TYPE_UNSPECIFIED = 0
CONNECTOR_TYPE_TYPE1 = 1
CONNECTOR_TYPE_TYPE2 = 2
CONNECTOR_TYPE_SCHUKO = 3
CONNECTOR_TYPE_CHADEMO = 4
Used in: Sample
string unit = 1
float value = 2
string type = 1
bool enabled = 2
optional string language = 3
optional I2c i2c = 4
string type = 1
string status = 2
string error = 3
optional Serial serial = 4
optional Modbus modbus = 5
ERROR_CODE_UNSPECIFIED = 0
ERROR_CODE_OTHER = 1
ERROR_CODE_CONNECTOR_LOCK_FAILURE = 3
ERROR_CODE_EV_COMMUNICATION_ERROR = 4
ERROR_CODE_GROUND_FAILURE = 5
ERROR_CODE_HIGH_TEMPERATURE = 6
ERROR_CODE_INTERNAL_ERROR = 7
ERROR_CODE_LOCAL_LIST_CONFLICT = 8
ERROR_CODE_OVER_CURRENT_FAILURE = 9
ERROR_CODE_OVER_VOLTAGE = 10
ERROR_CODE_POWER_METER_FAILURE = 11
ERROR_CODE_POWER_SWITCH_FAILURE = 12
ERROR_CODE_READER_FAILURE = 13
ERROR_CODE_RESET_FAILURE = 14
ERROR_CODE_UNDER_VOLTAGE = 15
ERROR_CODE_WEAK_SIGNAL = 16
Used in: Display, configuration.v1.Display
string address = 1
int32 bus = 2
string type = 1
bool enabled = 2
optional bool indicate_card_read = 3
optional int32 data_pin = 4
optional bool invert = 5
Used in: EVCC, PowerMeter, evse.v1.EVCC, evse.v1.PowerMeter
string protocol = 1
string device_address = 2
string type = 1
bool enabled = 2
optional Modbus modbus = 3
optional Spi spi = 4
Used in: charge_point.v1.ConnectionSettings, connection.v1.ConnectionSettings
PROTOCOL_VERSION_UNSPECIFIED = 0
PROTOCOL_VERSION_OCPP_16 = 1
PROTOCOL_VERSION_OCPP_201 = 2
Used in: evse.v1.GetUsageForEVSEResponse
optional Consumption consumption = 1
string measureand = 2
optional string phase = 3
optional string location = 4
optional string context = 5
Used in: EVCC, evse.v1.EVCC
string device_address = 1
uint32 baud_rate = 2
uint32 parity = 3
uint32 data_bits = 4
uint32 stop_bits = 5
Used in: PowerMeter, evse.v1.PowerMeter
int32 chip_select = 1
int32 bus = 2
string type = 1
bool enabled = 2
optional string device_address = 3
optional int32 reset_pin = 4