Get desktop application:
View/edit binary Protocol Buffers messages
bytes telemetry = 1
string address = 2
string telemetry_type = 3
int64 sent_at = 4
string contract_id = 1
repeated bytes telemetry = 2
string telemetry_type = 3
int64 sent_at = 4
Used in: HeadReportRequest
uint64 timestamp = 1
uint64 number = 2
string hash = 3
Used in: AutomationTelemWrapper
uint64 timestamp = 1
uint64 block_number = 2
string block_hash = 3
bytes config_digest = 4
string data_source = 1
double value = 2
int64 bridge_task_run_started_timestamp = 3
int64 bridge_task_run_ended_timestamp = 4
int64 provider_requested_timestamp = 5
int64 provider_received_timestamp = 6
int64 provider_data_stream_established = 7
int64 provider_indicated_time = 8
string feed = 9
string chain_id = 10
int64 observation = 11
string config_digest = 12
int64 round = 13
int64 epoch = 14
uint32 version = 32
string data_source = 1
double dp_benchmark_price = 2
double dp_bid = 3
double dp_ask = 4
bool dp_invariant_violation_detected = 33
string bridge_request_data = 35
int64 current_block_number = 5
string current_block_hash = 6
uint64 current_block_timestamp = 7
bool fetch_max_finalized_timestamp = 25
int64 max_finalized_timestamp = 26
uint32 observation_timestamp = 27
bool is_link_feed = 28
int64 link_price = 29
bool is_native_feed = 30
int64 native_price = 31
int64 bridge_task_run_started_timestamp = 8
int64 bridge_task_run_ended_timestamp = 9
int64 provider_requested_timestamp = 10
int64 provider_received_timestamp = 11
int64 provider_data_stream_established = 12
int64 provider_indicated_time = 13
string feed = 14
int64 observation_benchmark_price = 15
string observation_benchmark_price_string = 22
int64 observation_bid = 16
int64 observation_ask = 17
string observation_bid_string = 23
string observation_ask_string = 24
MarketStatus observation_market_status = 34
string config_digest = 18
int64 round = 19
int64 epoch = 20
string asset_symbol = 21
uint32 don_id = 36
string request_id = 1
string node_address = 2
repeated string domains = 3
string chainID = 1
optional Block latest = 2
optional Block finalized = 3
string bridge_adapter_name = 1
bytes bridge_request_data = 2
bytes bridge_response_data = 3
optional string bridge_response_error = 4
int32 bridge_response_status_code = 5
int64 request_start_timestamp = 6
int64 request_finish_timestamp = 7
bool local_cache_hit = 8
int32 spec_id = 9
optional uint32 stream_id = 10
string dot_id = 11
uint32 don_id = 12
uint64 seq_nr = 13
bytes config_digest = 14
int64 observation_timestamp = 15
uint32 stream_id = 1
int32 stream_value_type = 2
bytes stream_value_binary = 3
string stream_value_text = 4
optional string observation_error = 5
int64 observation_timestamp = 6
int64 observation_finished_at = 7
uint32 don_id = 8
uint64 seq_nr = 9
bytes config_digest = 10
Used in: EnhancedEAMercury
UNKNOWN = 0
CLOSED = 1
OPEN = 2
Used in: AutomationTelemWrapper
uint64 timestamp = 1
string node_version = 2
bytes config_digest = 3
Used as response type in: Telem.Telem, Telem.TelemBatch